Laser ablation plasma expansion using microwaves
HomeHome > Blog > Laser ablation plasma expansion using microwaves

Laser ablation plasma expansion using microwaves

Aug 03, 2023

Scientific Reports volume 13, Article number: 13901 (2023) Cite this article

118 Accesses

Metrics details

This study explores the potential of utilizing microwaves to sustain the expansion of transient laser ablation plasma of Zr target. By application of microwaves on the plasma, we observe a significant enhancement with a two to three order of magnitude increase in the plasma emission intensity, and 18 times increase in the plasma’s spatial volume. We investigate the temperature change of the plasma and observe that it decreases from 10,000 K to approximately 3000 K. Electron temperature decreased with volume expansion owing to increased surrounding air interaction, while the plasma can be sustained in air using microwaves. The increase in electron temperature during temperature drop is indicative of non-equilibrium plasma. Our results emphasize the contribution of microwaves in promoting enhanced emission and plasma formation at controlled, low temperature, thereby demonstrating the potential of microwaves to enhance the accuracy and performance of laser-induced breakdown spectroscopy. Importantly, our study suggests that microwaves could also mitigate the generation of toxic fumes and dust during ablation, a critical benefit when handling hazardous materials. The system we've developed is highly valuable for a range of applications, notably including the potential to reduce the possible emergence of toxic fumes during the decommissioning of nuclear debris.

Laser ablation plasma generates a breakdown plasma that rapidly expands in space and dissipates within nanoseconds to microseconds, finding widespread applications in instrumentation, medicine, and industry1, 2. It involves exposing a sample target to a pulsed laser, resulting in plasma with characteristics that can vary significantly owing to various factors, including self-absorption, reflection, and cooling. The control over the plasma characteristics can be demonstrated by the plasma emissions.

Analytical applications using laser-induced breakdown spectroscopy (LIBS)3,4,5,6,7,8,9,10,11,12,13 have proven to be a powerful tool in science and industry. The amount of plasma emission can vary greatly depending on the environmental conditions under which the plasma is generated, and its properties can be controlled for a range of applications such as low-pressure semiconductor manufacturing equipment14, 15, space applications in a vacuum, elemental analysis16,17,18, high-pressure internal combustion engines19, and deep-sea applications20. However, ablation plasmas are typically limited in their expansion due to system constraints, such as volume size change and plasma lifetime21, limitations that are being addressed by microwave-enhanced LIBS by combining microwaves and pulsed lasers resulting in a significantly improved performance of the system21,22,23,24,25,26,27,28,29,30,31,32. The emission intensity of the plasma is significantly enhanced by microwave superposition because microwave energy can sustain the plasma for a much longer period, allowing for more emission events to occur15, 22, 31, 33,34,35,36,37,38,39,40,41,42,43,44,45,46. In addition, the spatial volume of the plasma is expanded by two orders of magnitude, which further increases the amount of light emitted and detected by the system. This is critical for applications that require high sensitivity because even negligible changes in the amount of light emitted can significantly affect the accuracy of the measurement.

The laser-induced plasma in LIBS can exist in either equilibrium or nonequilibrium states47,48,49. It is crucial to understand the differences between equilibrium and nonequilibrium plasmas in LIBS to develop a more reliable and accurate analytical method as non-equilibrium plasma can result in enhanced or suppressed emission intensities of certain atomic or molecular lines50, 51. In the context of microwave-enhanced LIBS, we have observed distinct non-equilibrium characteristics, particularly in the rotational and vibrational temperatures. The rotational and vibrational temperatures21were measured to elucidate the rapid change in ablation plasma characteristics, indicating that plasma volume expansion leads to a decrease in vibrational temperature from 12,000 K to approximately 2200 K within 1 ms21. While many other processes are responsible or plasma expansion and it will not always be accompanied by a temperature drop, we theorized that the plasma expansion and temperature drop during the microwave-expansion and sustainment period (few microseconds after ablation) is caused by the increased interaction between the plasma and surrounding air atmosphere. The contribution of shock waves in the laser ablation process in microwave-couple ablation is considered insignificant due to the time delay between the laser firing and the penetration of microwaves into the laser-induced plasma. This delay occurs because the microwaves have to wait for the laser-induced plasma density to decrease below the critical density (~ 1010 to 1011 cm-3) required for microwave penetration. For a microwave radiation frequency of 2.45 GHz, this critical density is typically in the order of 7 × 1010 cm−352. During the sustainment of plasma in air, the electrons can be accelerated and maintained at a certain level during the microwave injection period. The physics of microwave-enhanced plasma can be demonstrated by comparing plasma temperatures and its sustainment in air.

Previous studies have demonstrated the effectiveness of microwave-enhanced LIBS in increasing the plasma emission intensity by two to three orders of magnitude, without significant crater enlargement23, 53,54,55. Various samples, including Al, Al2O3, Gd, Ce, Pb, Cr, and Zr have been optimized for microwave oscillation conditions, and Zr and Zr oxides have also been determined to increase the plasma emission intensity27, 56. Although the plasma generated by the laser and expanded plasma maintained by the microwave may have different characteristics, both exhibit nonequilibrium temperatures, as evidenced by non-equal rotational and vibrational temperatures24, 30.

Our target application in using microwave-enhanced LIBS is on nuclear fuel debris analysis for the decommissioning effort at the Fukushima Daiichi Nuclear Power Station in Japan31. As the inevitable power losses in remote LIBS and high radiation-induced light absorption persists, the microwaves ensure sustained and large ablations even at threshold ablation energies. To prepare for the actual nuclear debris analysis, we examine various debris-related materials, including concrete and stainless steel from the building structure, Zirconium and Zirconia from the fuel rod tunnels, Gd from the fuel rod cladding, and Ce as a surrogate for Uranium. In this study, we used Zr as a sample for laser ablation plasma.

In the standard generation process of the laser-only induced process, the plasma volume expansion and emission increase are primarily driven by the rapid heating and vaporization of the target material upon laser irradiation. In microwave-assisted laser ablation plasma, the volume expansion is accompanied by a temperature drop as the microwaves influence plasma dynamics. In this study, we employed microlasers, which are compact laser systems with small, rectangular YAG crystal (dimensions 3.0 × 3.0 × 10.0 mm3) to generate the laser-induced breakdown plasma of Zirconium and Zirconia targets for microwave-enhanced LIBS analysis23. We wanted to emphasize that the plasma temperature sustained in air differed significantly from the laser-induced ablation, as the plasma expansion is accompanied by a temperature drop suggesting a non-equilibrium state. In this state, the electron temperature measured through OI emissions decreased, eventually leading to a non-equilibrium plasma state which remained constant as it was sustained by the microwaves. These results address fundamental questions regarding the effects of microwaves on ablation, plasma temperature, and ionization dynamics.

Figure 1a illustrates the experimental setup of microwave-enhanced laser-induced breakdown spectroscopy (LIBS) with a microlaser38. The term “microlaser”, or microchip laser, describes the compact size and portability of the laser system. It is specifically designed to generate intense laser pulses for ablation and plasma formation on the target material. The microlaser utilized in the experiment is a composite ceramic (JOLD-120-QPXF-2P iTEC; JENOPTIK, FRG) that is end-pumped by an 808 nm laser diode powered by a 120 A, 200 W power supply (PS; PLWB168; UNITAC, Japan). The quasi-continuous wave is transmitted into the Nd:YAG of the microlaser and the Cr + 4:YAG acts as a saturable absorber, enabling passive Q-switching (> 60 μs) and emitting instantaneous laser pulses with a 1.0 mJ laser energy (849 ps pulse width and 1064 nm wavelength)57, 58. The composite ceramic and optical elements are housed in a 60 mm × 120 mm × 900 mm aluminum case. The laser output is transmitted into the beam splitter and InGaAs detector (DET08C/M; 800–1700 nm, bandwidth 5 GHz; Thorlabs, USA) with electrical pulses into the pulse generator, and this triggers microwaves and spectrometers. The same InGaAs detector was utilized directly to measure the laser pulse width, which was determined to be 0.849 ns. The 2.45 GHz microwaves was introduced by the helical coil with cross-reflector plates26. To minimize the reflected power, we employed an impedance tuner (three-stub tuner, Maury Microwave, USA) and monitored the power using power sensors of the directional coupler (440,000 series, Connecticut Microwave Corp, USA).

Experimental setup for microwave-enhanced laser-induced breakdown spectroscopy (LIBS) with micro-laser and the effects of microwaves on plasma formation. The elements depicted in the figure include three-tuber stubs for impedance matching (Stub), a pulse generator (Pulse Gen), a microwave generator (MW), an oscilloscope (Osc), and a photodiode (Diode).

The plasma emissions were analyzed using a double echelle-type spectrometer (λ/150,000, Super Damon, LTB, Germany) and a single type-echelle spectrometer (λ/50,000, EMU 120/65, Catalina Scientific, Arizona). The exposure time and gate width used in both spectrometers was 1.0 ms. The Super Demon double echelle-type spectrometer, due to its higher resolution, was used for time-series signal-to-noise ratio (SNR) measurements. However, this spectrometer has a narrow spectral range, thus, we used the Catalina echelle spectrometer for temperature measurements. Despite its lower resolution, this spectrometer has a broader spectral range, allowing us to capture the several other emissions aside from the Zr emissions.

Figure 1b shows the plasma formation on Zr metal samples with and without microwave irradiation. An ultrafast camera (Fastcam SA-Z, Photron, UK) was used to visualize plasma formation with the same synchronized signal as the laser firing. At 100,000 fps with an exposure time of 10 μs, a 720 × 380 pixels2 measurement area was captured. In all experimental conditions, a Tamron 180 mm AF macro lens (Saitama, Japan) was fixed at an aperture value of F/3.5 (representing the f-number, which is the ratio of the lens's focal length to the diameter of the entrance pupil) and a zoom ratio of 1:10. The images displayed were the largest observed plasma at 0 μs without microwaves and 1000 μs with microwaves.

To determine the plume circumference, we utilized image J analysis software and standard edge detection and pixel counting protocols. We then approximated the volume of the plasma as a hemispherical plume using the plume circumference. The estimation of the plasma plume volume as a hemisphere based on the plume circumference, while simplification, is a common approach in plasma physics, and we believe it's a valid first-order approximation in our case. This is, of course, dependent on the assumption that plasma expands symmetrically, which seems reasonable given our experimental setup and observations. It results in ablation volume significantly increases from 6.8 ± 0.1 to 125 ± 8 mm3 with the application of microwaves. The magnification is approximately 18 times, which is higher than the previously reported magnification of approximately ten times24. The observed plasma expansion of up to 18 times, compared to the previously reported 10 times, could be explained by two primary factors: microwave and laser parameters. When microwave parameters are held constant, the initial plasma size significantly impacts the enhancements, where larger initial sizes are likely to absorb more microwave energy, leading to more substantial expansions29. Nonetheless, we hypothesize that there is an optimal plasma size threshold, beyond which the efficiency of microwave-induced expansion could diminish. This hypothesis, however, requires further investigation for validation.

The superimposition of microwaves and laser-induced ablation functions as a near-field coupling system where the reactive near-field region is centered around the target area in close proximity to the antenna. In Fig. 2a, the microwave antenna position details are shown with values dx = dy = 0.1 mm and Ø = 30◦. A microwave power density of approximately 40 GW/m2, which corresponds to the maximum electric field of the antenna derived from HFSS simulation in reference and the radiation by the Poynting vector (E2/n, where E represents the electric field and n represents the intrinsic impedance), is delivered at a range of 0.1 mm from the target. This high-power density results to a significant enhancement of the laser-induced energy, initially at 1.6 GW/cm2. In the absorbed power measurements in Fig. 2b, the reflected power is subtracted from the forward power in realtime using the oscilloscope (DSO-X-3024A, AgilentTechnologies, Colorado, USA). We observed that the laser ablation plasma absorbs a significant amount of power at 0.981 J. During the initial 100 μs, the absorbed power is minimal, due to the high density of the laser ablation plasma, which impedes microwave propagation. During this period, we can only approximate and hypothesize that the plasma density is greater than critical plasma density of 7 × 1010 cm−3. Nevertheless, this absorbed power gradually escalates, reaching a maximum of 97.8% at around 60 μs. Factoring in both the absorbed power and our estimation of the plasma volume, we've calculated that the power density absorption by the plasma only approximates to 7.9 kW/cm3. It is hypothesized that this concentration of microwave energy may also influence the volume of fumes produced during the ablation process.

(a) The detailed diagram of the microwave antenna at dx = dy = 0.1 mm and Ø = 30◦. (b) The absorbed power plot was used to approximate the actual absorbed microwave power density by the enlarged plasma.

Figure 3 illustrates the outcome of laser-induced ablation conducted on the Zr oxide-based ceramic samples. The ablation procedure employed a laser energy of 1.0 mJ and microwave power of 1.0 kW. A three-dimensional (3D) microscopic camera (VHX-970FN, Keyence, Japan) with a resolution of 0.149 µm was utilized to capture the process and examine the surface ablation characteristics. The high melting temperatures of the Zr oxide-based ceramic samples, which reached 3,813 K, resulted in the formation of basin-like cavity profiles with side bumps that were easily discernible as shown in Fig. 3a. The point of origin in the crater’s depth is represented by a plain white color at the zero-micrometer mark, while the surrounding flat surface exhibits a range of light to dark pink colors, indicating the presence of elevated side bumps surrounding the crater. When microwaves were applied as shown in Fig. 3b, the diameter of the crater decreased, as the region near the antenna underwent less ablation. The volume of the side bump decreased; however, the depth increased. We speculated that microwaves contribute to the reduction of ablation crater volumes, which could in turn minimize the production of fumes and dust. This assumption seems to present an apparent contradiction with regards to the relationship between crater formation and plasma expansion where a more extensive material breakdown would be required to facilitate plasma expansion. To address this apparent discrepancy, we propose a hypothesis that the microwave-assisted breakdown of the side bumps facilitates plasma expansion. This hypothesis aligns with observed phenomena, as the plasma expansion is primarily outward and doesn’t infiltrate the crater's interior. Given our experimental setup, the laser's focal point is roughly located at the surface level and the focal depth is ~ 5 mm. Hence, with each succeeding laser shot, the ablation of materials slowly increase as laser drilling continues with increased laser shot.

Laser-induced ablation of Zr oxide-based ceramic samples: changes in crater diameter and side bump characteristics both (a) without and (b) with microwave application. The relative standard errors were based on uncertainty of the reference surface which are measured by (i) standard deviation of the surface roughness for the depth distance, bump volume, and crater volume and (ii) standard deviation of the minimum and maximum diameter.

In the absence of microwaves, a phenomenon known as plasma confinement occurs with an increase in the number of laser shots, leading to an enlargement of the crater’s volume. This observation is supported by the findings of Hernandez II et al., (2022)59, who reported an exponential increase in cavity size and depth with increased laser shots but eventually slows down due to plasma shielding effect. In the presence of microwaves, the enhancement is channeled upwards, inhibiting the progression of cavity enlargement. This unique mechanism allows microwaves to influence the plasma's depth and expansion. However, keep in mind that the microlaser device used is limited to the laser energy of 1 mJ. For larger laser energy, almost insignificant effects of microwave to ablation crater was observed on alumina surface21.

The recent results shows the potential of microwaves to reduce the ablation crater volume. The reason behind needs further investigation including microwave-induce breakdown and melting in the side bumps of the ablation with increased number of laser shots. This information is particularly significant in the context of dealing with toxic samples such as those encountered in our target application of nuclear debris decommissioning.

Figure 4 illustrates the plasma emission intensities of atomic Zr I (460 nm) and ionic Zr II (449 nm) emissions at varying gate delays. The red symbols representing the results of the standard LIBS system with superimposed microwaves and blue symbols representing the results without microwaves. As the we are interested with nuclear debris applications, the Zr I and Zr II lines may interfere with Uranium emissions especially within the 420–470 nm range. Figure 4a shows the plasma emission intensity, whereas the Fig. 4b illustrates the signal-to-noise ratio (SNR) calculated as a ratio to the background light. Both figures illustrate an enhancement effect of approximately two–three orders of magnitude in the presence of microwaves.

Effects of microwaves on the ablation plasma’s (a) emission intensity and (b) signal-to-noise ratio (SNR) of Zr samples.

Without microwaves, the ablation plasma disappears approximately 10 μs after the laser irradiation. However, when microwaves are superimposed, the ablation plasma is sustained in space for a longer duration. The plasma is maintained during the microwave input period, as indicated by the time change of the emission intensity and SNR value of the characteristic spectrum. The trends are consistent for the neutral and ion emissions, and the enhancement effect of the microwaves is approximately two to three-orders-of-magnitude.

Several other reports suggest an improved SNR only by a factor in the single or double digits as opposed to the two to three-orders-of-magnitude as other factors affect SNR including increased background noise by microwaves. Recently, we found that the peak SNR for conditions without microwaves occurs within the first microsecond after laser firing. This is a detail we've previously overlooked, as our focus has been primarily on plasma emissions coupled with microwaves. To be clear, the enhancements of two to three orders of magnitude only pertain to the same emissions at a gate delay between 1 and 10 μs. However, when comparing the optimal SNR under conditions with or without microwaves, the increase in SNR is merely in the single to double-digit range.

The enhanced and sustained plasma emission in the presence of microwaves can be attributed to several factors. The absorption of microwave energy by the plasma leads to sustainment and expansion of the plasma volume, which also enhances plasma emission owing to increased recombination and excitation processes. In addition, the continuous supply of energy provided by the microwaves may maintain the plasma in a non-equilibrium state for longer periods of time. The sustained plasma can provide more opportunities for atomic and molecular interactions, leading to enhanced emission intensities.

The plasma temperature is commonly determined via spectrum analysis, with previous reports indicating that the vibration temperature of 12,000 K is reduced to approximately 2200 K using stoichiometric plasma spectrum measurement via a nitrogen second positive system (N2PS)21, 30. The vibration, rotation, and electron temperatures indicate physical characteristics of plasma that temporally change as the plasma shifts from equilibrium to nonequilibrium, making them challenging to evaluate. Microwaves have capturing atomic, ionic, and molecular emissions from sustained plasma easier, allowing for a successful evaluation of the electron temperature using the Saha–Boltzmann equation which is based on thermal equilibrium plasma. While the microwave-coupled plasma may not exist in a state of thermal equilibrium, the Saha–Boltzmann equation still offers a useful heuristic for estimating the electron temperature, as supported by multiple sources including Reference 38. Thus, we propose using the emissions from the air and ablation plasma interaction, which increase with microwaves, to easily and quickly approximate the plasma temperatures. This interaction leads to the emission of molecular N2PS, OH, and OI.

In this study, we compared the plasma temperature characteristics using the electron temperature of the OI and discussed the temperature change of plasma expansion in space owing to microwave energy. We examined the microwave effect on electron temperature and its plasma sustainment in air. We performed high-resolution spectrometer measurements (λ/50,000) on two spectra of OI, 777.19 nm and 777.49 nm. Figure 5 illustrates the experimental results obtained via LIBS measurements using a microlaser with and without microwaves. These two OI spectra have different peak values depending on the presence or absence of microwaves; however, the microwaves also increase the continuum background light. We use spectrum comparison with the simulated spectra to calculate the electron temperature.

Comparison of OI triplet atomic emission in microwave-enhanced laser-induced breakdown spectroscopy (LIBS) with micro-laser.

Figure 6a illustrate the simulated spectrum of the O band using synthetic spectra (SPECAIR 3.0, Spectral Fit, France)18, 60 as the electron temperature is increased from 2000 to 8000 K. SPECAIR calculates emission intensities based on energy level transitions, expressed by the Eq. 1:

Temperature changes of OI spectrum and effect of microwaves pulse widths in microwave-enhanced laser-induced breakdown spectroscopy (LIBS) with micro-laser via (a) simulations in comparison to (b) actual measurements.

In this equation, hc represents Planck's constant multiplied by the speed of light, while 'st' is a small term accounting for lambda doubling and spin splitting, as outlined in Reference 59. We observe a change in the peak value at 777.41 nm as the electron temperature increases, with the graph normalized to the 777.19 nm peak value. Figure 6b illustrates the measurement results of the OI spectrum under different microwave conditions. We also demonstrate the change in the 777.41 nm peak value, which is normalized to the 777.19 nm peak value, as the electron temperature increases. The microwave conditions are measured by changing the pulse from 0, 60, 70, 80, and 500 µs. Previous reports21 revealed that measurements of microwave absorbed power indicated exponential increase similar to the volume expansion of the ablation plasma within the first 100 µs. Beyond this period, both the absorbed power and volume expansion tend to stabilize or reach saturation levels; as such, our detailed measurements were conducted within the 100 µs timeframe. We note that the spectrum measured with a λ/50,000 spectroscope appears to be less smooth than the synthetic simulated spectrum. Regarding the normalized peak value at 777.41 nm, we’ve observed a trend of increasing values with increasing microwave input time. This trend aligns with the decreasing electron temperatures observed in the simulated spectra.

The effects of microwave pulse width on the electron temperature with 1.0 kW microwave are shown in Fig. 7. The electron temperature is approximately 10,000 K under the condition of no microwave input and drops to 6,000 K with microwave pulse width of 60 µs. From pulse width of 60–80 µs, the temperature fluctuates from 4000 to 6000 K. Subsequently, at microwave pulse width of 500 µs, the temperature slowly drops to 3000 K. The uncertainties of the measurements are around 1000 K, and all measurements were rounded to the nearest thousand.

Comparison of electron temperature with microwave input period in microwave-enhanced laser-induced breakdown spectroscopy (LIBS) with micro-laser.

We previously observed a striking similarity in the pattern of microwave power absorption to the pattern of temporal variations of electron temperature in air24. This observation suggests there is a correlation between the broadening of the microwave pulse and the time-variable alterations in electron temperature.

The increase in plasma volume due to microwave injection is 18 times larger which is accompanied by the electron temperature drops, after which the microwave injection sustained the non-equilibrium state of the plasma. Without microwaves, the plasma volume expansion and emission increase were driven by plasma relaxation and recombination effects, which result in a decrease in electron temperature and an increase in volume. This is distinctly different in the presence of microwaves, where the decrease in electron temperature does not result in a halt of plasma expansion. Instead, the microwaves cause a sustained level of electron excitation and activity, facilitating further plasma expansion.

Figure 8 illustrates the temporal absorbed microwave power for various microwave pulse widths ranging from 100 to 1000 μs. As shown in Fig. 8a, the microwave power absorbed by the laser ablation plasma consistently reached a maximum of over 98% for each pulse used. Figure 8b provides a more detailed view of the absorbed power during the initial 100 μs. Initially, the absorbed power is minimal due to the high density of the laser ablation plasma, which acts as a barrier to microwave propagation. However, this situation changes as time progresses; the absorbed power gradually increases, peaking at > 98% around the 60 μs mark. This trend—of minimal initial absorption followed by a gradual increase—is consistent across all varied microwave pulse widths. This consistency suggests a general relationship between microwave pulse width and temporal variations in microwave power absorption in laser ablation plasma.

Measurements of temporal absorbed microwave power under two different conditions: (a) varying the microwave pulse width, and (b) within the first 80 μs.

Through this research, we have demonstrated the potential of utilizing microwaves to enhance the expansion of transient laser-induced ablation plasma generated by a Zr target. Our experimental design included a microwave helical antenna, serving as a near-field coupling system. The antenna delivered an approximate power density of 1.2 GW/m2 within a range of 0.1 mm from the target, leading to a remarkable enhancement of laser-induced ablation plasma. The power absorption initially remained minimal, peaking at 97.8% around 60 μs, corresponding to an absorbed power density of 7.9 GW/cm3. This power influx underlies the observed enhancement in plasma emission intensity and spatial volume by two to three orders of magnitude. The additional energy provided by the microwaves not only drives the excitation and ionization processes within the plasma, but also fuels its expansion.

Our experimental observations also revealed some challenges. We observed that the placement of the antenna in relation to the target has a bearing on the successful application of microwave-induced plasma expansion. Antenna-target distance and the enhancement factor did not seem to exhibit a direct correlation (refer to Supplemental Figs. 1 and 2), suggesting that other factors are be at play. However, adjusting the angle of the antenna relative to the laser propagation showed more consistent results. Smaller angular values resulted in higher emission enhancements. Hence, maintaining a consistent antenna-target distance of 0.1 mm and an antenna angle of 30 degrees from the laser propagation was key to achieving successful microwave-induced plasma expansion.

In terms of ablation formation on Zr oxide-based ceramic samples, we observed the formation of basin-like cavities. The application of microwaves led to a reduction in crater diameter and an increase in depth, indicating a potential influence of microwave energy on the volume of fumes produced during the ablation process. This observation marks a departure from previous studies that reported negligible effects of microwaves on ablation craters21. Both these observations have implications in fields such as toxic sample analysis and nuclear debris decommissioning.

Furthermore, we have investigated the temperature change of the plasma with and without the applied microwaves using the OI emissions. These emissions potentially arise from the ablation of the Zinc oxide layer or from interaction with the atmospheric air environment. Without microwave application, the electron temperature of the plasma was approximately 10,000 K. On the other hand, with microwave application, the electron temperature of the plasma initially dropped to 6000 K with microwave pulse width of 100 μs and then to 3000 K using higher microwave pulse width. This decrease in temperature is attributed to the expansion of the plasma, which subsequently increases interaction with atmospheric air environments. Expanding on this matter, a decrease in temperature should not be loosely associated with a reduction in volume as the electron temperature, electron density, and volume, are shaped by a variety of factors. This includes the influence of external forces, such as microwaves, on plasma. In our study, the microwaves not only sustained electron motion but also induced plasma expansion, leading to the observed temperature decrease. One likely reason for this decrease in temperature in an expanding plasma is the non-equilibrium nature of the plasma.

In previous study, we noted a decrease in the vibrational temperature in nitrogen molecules in air as the microwaves expanded the plasma, thereby increasing plasma-air interactions. We can thus confirm the formation of non-equilibrium plasma by the microwaves in both air plasmas and ablation plasmas. These findings demonstrate that the use of microwaves in laser-induced ablation has important implications for various applications, such as toxic sample analysis and nuclear debris decommissioning. The microwave-enhanced ablation plasma presented in this study could also be used for other applications such as material processing and micro/nano fabrication, where controlling plasma expansion and energy deposition is crucial. Overall, our study opens up new avenues for the development of more efficient and effective laser-based techniques for various applications.

We developed a novel system that utilizes microwaves to enhance laser-induced ablation with microlaser. By superimposing microwaves on the laser ablation plasma, we induced breakdown by laser irradiation, and the ablated plasma was expanded and sustained in space by the microwaves. This expanded plasma was determined by the microwave energy and its injection time, independent of the initial laser conditions. Our results demonstrate that after breakdown, the plasma expands up to 18 times the initial size by absorbing microwaves.

We also investigated temperature changes in the plasma in the presence of microwaves. We wanted to emphasize that the electron temperature sustained in air differed significantly from the laser-induced ablation, as it was in a non-equilibrium state. In this state, the electron temperature was initially 10,000 K dropped to approximately 4000 K in approximately 100 µs. Subsequently, even with the application of microwaves, the electron temperature dropped to approximately 3000 K, and this state was maintained in space.

Our study provides new insights into the dynamics of plasma expansion and temperature changes in microwave-enhanced LIBS with a microlaser. The microwave can contribute to sustaining and expanding the plasma in air while decreasing the electron temperature. Our findings have important implications for various applications, including toxic sample analysis and nuclear debris decommissioning. The developed system may have significant potential for enhancing the sensitivity and selectivity of LIBS in various fields.

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request by contacting Yuji Ikeda at [email protected].

Smirnov, B. M. Physics of Ionized Gases.

Bellan, P. M. Fundamentals of Plasma Physics.

Harilal, S. S., Freeman, J. R., Diwakar, P. K. & Hassanein, A. Femtosecond Laser ablation: Fundamentals and applications. In Laser-Induced Breakdown Spectroscopy: Theory and Applications (eds Musazzi, Sergio & Perini, Umberto) 143–166 (Springer, 2014). https://doi.org/10.1007/978-3-642-45085-3_6.

Chapter Google Scholar

Gamez, G., Bogaerts, A., Andrade, F. & Hieftje, G. M. Fundamental studies on a planar-cathode direct current glow discharge. Part I: Characterization via laser scattering techniques. Spectrochim. Acta Part B: Atom. Spectrosc. 59(4), 435–447. https://doi.org/10.1016/j.sab.2003.12.002 (2004).

Article ADS CAS Google Scholar

Rusak, D. A., Castle, B. C., Smith, B. W. & Winefordner, J. D. Fundamentals and applications of laser-induced breakdown spectroscopy. Crit. Rev. Anal. Chem. 27, 257–290 (1997).

Article CAS Google Scholar

Rohwetter, P. et al. Remote LIBS with ultrashort pulses: Characteristics in picosecond and femtosecond regimes. J. Anal. At. Spectrom. 19, 437–444 (2004).

Article CAS Google Scholar

Zhang, Z., Li, T. & Huang, S. Influence of the pressure and temperature on LIBS for gas concentration measurements. Spectrochim. Acta Part B At Spectrosc. 155, 24–33 (2019).

Article ADS CAS Google Scholar

Thakur, S. N. & Singh, J. P. Fundamentals of LIBS and recent developments. In Laser-Induced Breakdown Spectroscopy 3–22 (Elsevier, 2020). https://doi.org/10.1016/B978-0-12-818829-3.00001-0.

Chapter Google Scholar

Rai, V. N. & Thakur, S. N. Instrumentation for LIBS and recent advances. In Laser-Induced Breakdown Spectroscopy 107–136 (Elsevier, 2020). https://doi.org/10.1016/B978-0-12-818829-3.00005-8.

Chapter Google Scholar

Rai, V. N. & Thakur, S. N. Physics and dynamics of plasma in laser-induced breakdown spectroscopy. In Laser-Induced Breakdown Spectroscopy 71–106 (Elsevier, 2020). https://doi.org/10.1016/B978-0-12-818829-3.00004-6.

Chapter Google Scholar

Thakur, S. N. Atomic emission spectroscopy. In Laser-Induced Breakdown Spectroscopy 23–40 (Elsevier, 2020). https://doi.org/10.1016/B978-0-12-818829-3.00002-2.

Chapter Google Scholar

Zhang, Y., Zhang, T. & Li, H. Application of laser-induced breakdown spectroscopy (LIBS) in environmental monitoring. Spectrochim. Acta Part B At Spectrosc. 181, 106218 (2021).

Article CAS Google Scholar

Mohamed, W. T. Y. Improved LIBS limit of detection of Be, Mg, Si, Mn, Fe and Cu in aluminum alloy samples using a portable Echelle spectrometer with ICCD camera. Opt. Laser Technol. 40, 30–38 (2008).

Article ADS CAS Google Scholar

Horikoshi, S. & Serpone, N. RF Power Semiconductor Generator Application in Heating and Energy Utilization (Springer, 2020). https://doi.org/10.1007/978-981-15-3548-2.

Book Google Scholar

Ikeda, Y. Development of 2.45 GHz semiconductor microwave system for combustion ignition enhancement and failure analysis. Materials 15(6), 2042. https://doi.org/10.3390/ma15062042 (2022).

Article ADS CAS PubMed PubMed Central Google Scholar

Deak, N., Bellemans, A. & Bisetti, F. Plasma-assisted ignition of methane/air and ethylene/air mixtures: Efficiency at low and high pressures. Proc. Combust. Inst. 38, 6551–6558 (2021).

Article CAS Google Scholar

Vidmar, R. & Stalder, K. Air Chemistry and power to generate and sustain plasma: Plasma lifetime calculations. in 41st Aerospace Sciences Meeting and Exhibit (American Institute of Aeronautics and Astronautics, 2003). https://doi.org/10.2514/6.2003-1189

Laux, C. O., Spence, T. G., Kruger, C. H. & Zare, R. N. Optical diagnostics of atmospheric pressure air plasmas. Plasma Sources Sci Technol 12, 125–138 (2003).

Article ADS CAS Google Scholar

Yiguang, J. & Sun, W. Plasma assisted combustion: Dynamics and chemistry Progr. Energy Combust. Sci. 48(21), 83. https://doi.org/10.1016/j.pecs.2014.12.002 (2015).

Article Google Scholar

Bowen, H. J. M. Strontium and barium in sea water and marine organisms. J. Marine Biol. Assoc. U. K. 35(3), 451–460. https://doi.org/10.1017/S0025315400010298 (1956).

Article CAS Google Scholar

Ikeda, Y., Soriano, J. K. & Wakaida, I. The interactions of microwaves with alumina surface in microwave-enhanced laser-induced breakdown spectroscopy. Opt. Laser Technol. 159, 108982 (2023).

Article CAS Google Scholar

Ofosu, J. A. & Ikeda, Y. Elemental analysis and mixture ratio determination in fine powder metals using microwave-sustained plasma ball spectroscopy. Spectrochim. Acta Part B At Spectrosc. 160, 105693 (2019).

Article CAS Google Scholar

Yuji, I., Kim, S. J. & Ikuo, W. Microwave-enhanced laser-induced breakdown spectroscopy of Zirconium metal. Talanta Open 7, 100182 (2023).

Article Google Scholar

Ikeda, Y. & Soriano, J. K. Microwave-enhanced laser-induced air plasma at atmospheric pressure. Opt Express 30, 33756 (2022).

Article ADS CAS PubMed Google Scholar

Ikeda, Y., Soriano, J. K. & Wakaida, I. Signal-to-noise ratio improvements in microwave-assisted laser-induced breakdown spectroscopy. Talanta Open 6, 100138 (2022).

Article Google Scholar

Ikeda, Y., Hirata, Y., Soriano, J. K. & Wakaida, I. Antenna characteristics of helical coil with 2.45 ghz semiconductor microwave for microwave-enhanced laser-induced breakdown spectroscopy (MW-LIBS). Materials 15, 2851 (2022).

Article ADS CAS PubMed PubMed Central Google Scholar

Ikeda, Y., Soriano, J. K., Ohba, H. & Wakaida, I. Analysis of gadolinium oxide using microwave-enhanced fiber-coupled micro-laser-induced breakdown spectroscopy. Sci. Rep. https://doi.org/10.1038/s41598-023-32146-x (2023).

Article PubMed PubMed Central Google Scholar

Khumaeni, A., Akaoka, K., Miyabe, M. & Wakaida, I. The role of metastable atoms in atomic excitation process of magnesium in microwave-assisted laser plasma. Opt. Commun. 479, 126457 (2021).

Article CAS Google Scholar

Ikeda, Y., Soriano, J. K., Kawahara, N. & Wakaida, I. Spatially and temporally resolved plasma formation on alumina target in microwave-enhanced laser-induced breakdown spectroscopy. Spectrochim. Acta Part B At Spectrosc. 197, 106533 (2022).

Article CAS Google Scholar

Ikeda, Y. & Soriano, J. K. Analysis of the characteristics of microwave-enhanced laser-induced atmospheric air plasma and ablation plasma for Al target. Talanta Open 7, 100172 (2023).

Article Google Scholar

Ikeda, Y., Ofosu, J. A. & Wakaida, I. Development of microwave-enhanced fibre-coupled laser-induced breakdown spectroscopy for nuclear fuel debris screening at Fukushima. Spectrochim. Acta Part B At Spectrosc. 171, 105933 (2020).

Article CAS Google Scholar

Khumaeni, A., Miyabe, M., Akaoka, K. & Wakaida, I. The effect of ambient gas on measurements with microwave-assisted laser-induced plasmas in MA-LIBS with relevance for the analysis of nuclear fuel. J. Radioanal. Nucl. Chem. 311, 77–84 (2017).

Article CAS Google Scholar

Hayashi, J. et al. Effects of microwave-enhanced plasma on laser ignition. In Ignition Systems for Gasoline Engines (eds Günther, Michael & Sens, Marc) 245–253 (Springer, 2017). https://doi.org/10.1007/978-3-319-45504-4_14.

Chapter Google Scholar

Ikeda, Y., Moon, A. & Kaneko, M. Development of microwave-enhanced spark-induced breakdown spectroscopy. Appl. Opt. 49(13), C95. https://doi.org/10.1364/AO.49.000C95 (2010).

Article CAS Google Scholar

Al Shuaili, A. A., Al Hadhrami, A. M., Wakil, M. A. & Alwahabi, Z. T. Improvement of palladium limit of detection by microwave-assisted laser induced breakdown spectroscopy. Spectrochim. Acta Part B At Spectrosc. 159, 105666 (2019).

Article CAS Google Scholar

Tang, Y. et al. Multielemental self-absorption reduction in laser-induced breakdown spectroscopy by using microwave-assisted excitation. Opt Express 26, 12121 (2018).

Article ADS CAS PubMed Google Scholar

Chen, S. J., Iqbal, A., Wall, M., Fumeaux, C. & Alwahabi, Z. T. Design and application of near-field applicators for efficient microwave-assisted laser-induced breakdown spectroscopy. J. Anal. At. Spectrom. 32, 1508–1518 (2017).

Article CAS Google Scholar

Tampo, M. et al. Enhancement of intensity in microwave-assisted laser-induced breakdown spectroscopy for remote analysis of nuclear fuel recycling. J. Anal. At. Spectrom. 29, 886–892 (2014).

Article CAS Google Scholar

Ikeda, Y. Determining the detection limit of strontium, calcium, and Lead in an aqueous jet using microwave-enhanced plasma-ball optical emission spectrometry. Talanta Open 6, 100137 (2022).

Article Google Scholar

Viljanen, J., Zhao, H., Zhang, Z., Toivonen, J. & Alwahabi, Z. T. Real-time release of Na, K and Ca during thermal conversion of biomass using quantitative microwave-assisted laser-induced breakdown spectroscopy. Spectrochim. Acta Part B At Spectrosc. 149, 76–83 (2018).

Article ADS CAS Google Scholar

Ikeda, Y. & Ofosu, J. A. Optimization of microwave discharge igniter for ignition enhancement: Effect of microwave oscillation pattern on induced plasmas.

Ikeda, Y. & Tsuruoka, R. Characteristics of microwave plasma induced by lasers and sparks. Appl.Opt. 51(7), B183. https://doi.org/10.1364/AO.51.00B183 (2012).

Article CAS PubMed Google Scholar

Viljanen, J., Sun, Z. & Alwahabi, Z. T. Microwave assisted laser-induced breakdown spectroscopy at ambient conditions. Spectrochim. Acta Part B At Spectrosc. 118, 29–36 (2016).

Article ADS CAS Google Scholar

Camps, E., Campos-González, E. & Rivera-Rodríguez, C. Characterization of the combination of microwave and laser ablation plasmas. Surf. Coat. Technol. 422, 127509 (2021).

Article CAS Google Scholar

Ikeda, Y. Atmospheric air plasma sustainment by semiconductor microwave for hydroxyl radical production and powder metal element analysis. Opt. Express 30, 29868 (2022).

Article CAS PubMed Google Scholar

Khumaeni, A., Motonobu, T., Katsuaki, A., Masabumi, M. & Ikuo, W. Enhancement of LIBS emission using antenna-coupled microwave. Opt. Express 21, 29755 (2013).

Article ADS PubMed Google Scholar

Miziolek, A., Palleschi, V. & Schechter, I. Laser-Induced Breakdown Spectroscopy (LIBS): Fundamentals and Applications. (2006).

Musazzi, S. & Perini, U. Springer Series in Optical Sciences 182 Laser-Induced Breakdown Spectroscopy Theory and Applications. http://www.springer.com/series/624 (2014).

Singh, J. P. & Suria, T. N. Laser-Induced Breakdown Spectroscopy. (2007).

Correale, G. et al. Non-Equilibrium Plasma Ignition for Internal Combustion Engines.

di Sarli, V. & di Benedetto, A. Effects of non-equidiffusion on unsteady propagation of hydrogen-enriched methane/air premixed flames. Int. J. Hydrogen Energy 38, 7510–7518 (2013).

Article Google Scholar

Liu, Y., Baudelet, M. & Richardson, M. Elemental analysis by microwave-assisted laser-induced breakdown spectroscopy: Evaluation on ceramics. J. Anal. AtOM. Spectrom. 25, 1316 (2010).

Article CAS Google Scholar

Matsumoto, A. et al. Fiber-optic laser-induced breakdown spectroscopy of zirconium metal in air: Special features of the plasma produced by a long-pulse laser. Spectrochim. Acta Part B At Spectrosc. 142, 37–49 (2018).

Article ADS CAS Google Scholar

Ruas, A., Matsumoto, A., Ohba, H., Akaoka, K. & Wakaida, I. Application of laser-induced breakdown spectroscopy to zirconium in aqueous solution. Spectrochim. Acta Part B At Spectrosc. 131, 99–106 (2017).

Article ADS CAS Google Scholar

Miškovičová, J., Anguš, M., van der Meiden, H. & Veis, P. Selection of molybdenum lines by quantitative analysis of molybdenum- zirconium-titanium alloy by CF-LIBS for future fusion applications. Fusion Eng. Des. 153, 111488 (2020).

Article Google Scholar

Nakanishi, R., Saeki, M., Wakaida, I. & Ohba, H. Detection of gadolinium in surrogate nuclear fuel debris using fiber-optic laser-induced breakdown spectroscopy under gamma irradiation. Appl. Sci. 10, 8985 (2020).

Article CAS Google Scholar

Tamura, K., Nakanishi, R., Ohba, H., Taira, T. & Wakaida, I. Recovery of the laser-induced breakdown spectroscopy system using a ceramic microchip deteriorated by radiation for the remote elemental analysis. J. Nucl. Sci. Technol. https://doi.org/10.1080/00223131.2022.2091056 (2022).

Article Google Scholar

Tamura, K. et al. Radiation dose rate effects on the properties of a laser-induced breakdown spectroscopy system developed using a ceramics micro-laser for fiber-optic remote analysis. J. Nucl. Sci. Technol. 58, 405–415 (2021).

Article CAS Google Scholar

Hernandez, J. E. A. II., Yamada, S., Sasaki, S., Caatapang, A. V. & Wada, M. Influence of target cavity formation on the emission spectra of nanosecond laser ablation plasmas. Plasma Fusion Res. 17, 2406018–2406018 (2022).

Article ADS Google Scholar

Packan, D., Laux, C. O., Gessman, R. J., Pierrot, L. & Kruger, C. H. Measurement and Modeling of OH, NO, and CO Infrared Radiation at 3400 K. J. Thermophys. Heat Trans. 17, 450–456 (2003).

Article CAS Google Scholar

Download references

This work was supported by JAEA Nuclear Energy S&T and Human Resource Development Project via concentrating wisdom Grant Number JPJA20P20337946.

i-Lab., Inc., #213 KIBC Bldg., 5-5-2 Minatojima-Minami, Chuo, Kobe, 650-0047, Japan

Yuji Ikeda & Joey Kim Soriano

Collaborative Laboratory for Advanced Decommissioning Science, Japan Atomic Energy Agency (JAEA), 2-4 Shirakata, Tokai-Mura, Naka-Gun, Ibaraki, 319-1195, Japan

Hironori Ohba

National Institutes for Quantum Science and Technology (QST), 2-4 Tokai-Mura, Naka-Gun, Ibaraki, 319-1106, Japan

Hironori Ohba

Collaborative Laboratory for Advanced Decommissioning Science, Japan Atomic Energy Agency (JAEA), 790-1 Motooka, Tomioka-Machi, Futaba-Gun, Fukushima, 979-1151, Japan

Ikuo Wakaida

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

J.S. was responsible for the collection of data and preparation of figures. Y.I. supervised the experimentation in i-Lab, Inc. I.W., and H.O. supervised the collection of spectroscopic data in JAEA. All authors reviewed the manuscript.

Correspondence to Yuji Ikeda.

The authors declare no competing interests.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and Permissions

Ikeda, Y., Soriano, J.K., Ohba, H. et al. Laser ablation plasma expansion using microwaves. Sci Rep 13, 13901 (2023). https://doi.org/10.1038/s41598-023-41208-z

Download citation

Received: 22 March 2023

Accepted: 23 August 2023

Published: 25 August 2023

DOI: https://doi.org/10.1038/s41598-023-41208-z

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.